Transport
A summary of relevant experience includes:
- Risk Assessment/Safety management for London Underground Limited, CrossRail and MerseyRail, including QRA of tunnel ventilation system, cooling and ventilation of stationary trains,
- Station Fire Risk assessments for Merseyrail.
- Fire Risk Assessments for Railtrack principal surface & sub-surface stations.
- Jubilee Line Extension evacuation modelling.
- Leader for Fire Risk Assessments/Fire Safety Design for Atomic Weapons Establishments, which incorporate extensive “contained” areas and innovative solutions for means of escape.
- Extensive experience in developing smoke control strategies and escape from basement FM tunnels (these tunnels contain robotic systems, span hospital sites and also connect to the energy centres)
- Risk Assessment;. Methane ingress for Heathrow Express tunnel.
- Stansted Airport and Heathrow Terminal 3 CFD Modelling, including interface with tunnel system
- Design of an innovative vertical blast screen to replace the traditional raking and baffled blast screens used at Heathrow and other airports; thereby releasing a 2.9m wide strip of valuable airside land that could otherwise be put to more productive use
- Retained as Expert Witness for Scandinavian Star Ferry disaster.